Product > Online UPS > External Battery
CL Series  UPS
     SALIENT FEATURES
    On- line UPS CL SERIES 5-10KVA
       • High frequency & double conversion online technology
       • Fully Digital microprocessor control
       • Wide input voltage range
       • Near unity input power factor
       • High AC-AC efficiency
       • Cold start capability
       • LCD display
       • Simple & user friendly operation
       • Emer gency power offfunction option
       • Advance battery management
       • EMI/RFI noise filter
       • Optional parallel capacity (up to four ups)
       • Optional SNMP card slot
       • Smart RS-232 communication eith monitoring software
    CL SERIES UPS -10-20 KVA
       • Maximum reliability result of robustdesign & online double convers ion topology
       • Ideal for the most demanding electrical environments
       • Higher KVA models with .9 output power factor
       • Easy portability because of cold start on battery power
       • Automatic bypass
       • Longer runtime on external battery power
       • LCD user interface on front panel for regular status indication
       • RS-232 USB & intelligent slot c ommunication ports
       • Power management suite bundled
    TECHNICAL INFORMATION / SPECIFICATIONS (On-line Sinewave UPS)
    UPS Model Online UPS 6K Online UPS 6KS* Online UPS 10K Online UPS 10KS*
    Capacity & Output 6000VA/5400W 6000VA/5400W 10000VA/9000W 10000VA/9000W
    Input  
    Acceptable Input Voltage 110 ~ 276VAC
    Adjustable Bypass Voltage 110 ~ 276VAC
    Frequency Range 45Hz ~ 55Hz / 54Hz ~ 66Hz
    Phase Single Phase with ground
    THDI <5% with R full load
    Power Factor ≥0.99 @ R full load 
    Output  
    Voltage 208/220/230/240VAC
    Voltage Regulation <1%
    Frequency (Synchronised Range) 45Hz ~ 55Hz / 54Hz ~ 66Hz
    Frequency (Battery Mode) 50/60 ± 0.05Hz
    Current Crest Ratio 3:1
    Harmonic Distortion ≤2% @ Linear Load , ≤5% @Non-Linear Load
    Output Waveform Pure Sine Wave
    Overload Capacity
    Line Mode 2min @ 105% ~ 125% load
    30s @ 125% ~ 150% load
    1s @ >150% Load
    BAT Mode
    Parallel Upto 4
    Efficiency  
    Line Mode >92% @ full load & Battery fully charged
    BAT Mode >92% @ full load & 12VDC/Battery
    ECO Mode >96% @ full load & Battery fully charged
    Battery  
    No. of Internal Battriexs per set 20 Depending on the capacity of external batteries 20 Depending on the capacity of external batteries
    Battery Type 12V / 7AH 12V / 9Ah
    Backup Time (Full Load) >5 Minutes >5 Minutes
    Recharge Time 5 Hrs to 90% 5 Hrs to 90%
    Charging Current (max) 1.2A 4.0A 1.2A 4.0A
    Rated Battery Voltage 240VDC
    Transfer Time        
    BAT <- - > LINE 0ms
    INV <- - > BYPASS 0ms
    ECO <- -> INV <10ms
    Indicator        
    LCD Load Level / Battery Level / Battery Mode / AC Mode / Bypass Mode / Fault
    Audible Alarm        
    Battery Mode Sounding every 4 seconds
    Low Battery Sounding every second
    Fault Continuosly Sounding
    Overload Sounding twice every second
    Dimension        
    Tower Case (W x H x L) mm 260 x 708 x 550
    Environment        
    Operating Environment 0 - 40° C
    Relative Humidity 0-95% (Non-Condensing)
    Noise Level <50db @ 1 meter
    Interface        
    RS232 / USB Software supports Windows family, Linux, Sun Solarix, IBM Aix, Compaq True 64, SGI IRIX, Free BSD, HP-UX and MAC
    External Slot SNMP / AS 400 / Relay Card
    EPO Emergency Power off
Designed & Maintenance By Arihant Webtech