DC Power Supplies - Model E61

The E61 is a Constant Voltage/Constant Current, multi-output power supply with digital metering. It features four adjustable regulated DC outputs : 0 to 30V at 2A, ±3C to ±15V at 1A, 5V to 6V at 5A. The 0 to 30V supply is, additionally, a supply with automatic crossover when the load current exceeds the value established by the current limit setting. An independent current control allows the current limit to be set to any value within the current rating, enabling the supply to be used as a constant current source of regulation better than 0.2% and with compliance voltage up to 30V.

The ± 3V to ± 15V dual tracking supply features a tracking inaccuracy of less than ± 1% and finds wide application in the testing of linear circuits that require accurately set, equal and opposite DC voltages. The 5V to 6V supply doubles as a logic supply and as a supply for powering 6V battery operated equipment. All outputs are completely protected against short circuit and overload conditions.

 
SALIENT FEATURES
  • Independently adjustable outputs
  • CV/CC supply with automatic crossover
  • ±15V, Dual tracking supply
  • 5V, Logic Supply
  • Digital metering of all outputs
  • 3 1/2 digit LED display
  • Push-button selection of meter function and resolution
  • Meter accessible for external voltage measurements
  • All outputs short-circuit protected
  • Compact, bench-top unit, sources over 120 Watts
   TECHNICAL INFORMATION / SPECIFICATIONS

OUTPUTS

Parameter

V1

+V2

-V2

V3

Range

0 to 30V
Variable

+3V to +15V
Variable

-3V to -15V
Variable

5V to 6
Variable

Max. Load

2A

1A

1A

5A

Load regulation (CV)

±(0.03% + 3mV)

±(0.03% + 3mV)

±(0.06% + 6mV)

±(0.03% + 3mV)

Line Regulation (CV)

------------------------- ±(0.03% + 2mV)-----------------------------------------------------

Tracking Error

-------------------------V2 tracks + V1 within ± 1%------------------------------------------

Ripple (CV)

-------------------------Less than 1 mVr ms----------------------------------------------------

Noise (CV)

-------------------------Less than 10mV p-p, upto 15 MHz--------------------------------------

Load Regulation
(CC) upto 30V

2mA
±0.2%

-

-

-

Line Regulation
(CC) for ± 10%
Mains Var.

±0.2%

-

-

-

Ripple (CC)

Less than 20mA rms

-

-

-

Noise (CC)

Less than 20mA p-p

-

-

-

Load effect, transient recovery time

----------------- 400 µs to within 5mV of output setting for a NL to FL change.----------------

Output Protection

--------------------------Short-circuit proof------------------------------------------------------

Metering Accuracy

± (0.25% rdg + 1 dgt) for voltage and ± (0.5% rdg + 1 dgt) for current

Resolution

10mV upto 20V
100mV upto 30V
10mA upto 2A

10mV

10mV

10mV

GENERAL

DVM External Input

Ranges : 20V, 200V DC
Resolution : 10mV, 100mV
Accuracy : ±(0.25% rdg + 1 dgt.)

Power Input

230 VAC±10%, 50Hz

Operating Temperature

0°C to 40°C

Dimensions (mm)

317w x 87H x 380D

Weight (approx.)

8 Kg