The E61 is a Constant Voltage/Constant Current, multi-output
power supply with digital metering. It features four adjustable regulated
DC outputs : 0 to 30V at 2A, ±3C to ±15V at 1A, 5V to 6V
at 5A. The 0 to 30V supply is, additionally, a supply with automatic crossover
when the load current exceeds the value established by the current limit
setting. An independent current control allows the current limit to be
set to any value within the current rating, enabling the supply to be
used as a constant current source of regulation better than 0.2% and with
compliance voltage up to 30V.
The ± 3V to ± 15V dual tracking supply features a tracking
inaccuracy of less than ± 1% and finds wide application in the
testing of linear circuits that require accurately set, equal and opposite
DC voltages. The 5V to 6V supply doubles as a logic supply and as a supply
for powering 6V battery operated equipment. All outputs are completely
protected against short circuit and overload conditions.
|
| |
| SALIENT FEATURES |
- Independently adjustable outputs
- CV/CC supply with automatic crossover
- ±15V, Dual tracking supply
- 5V, Logic Supply
- Digital metering of all outputs
- 3 1/2 digit LED display
- Push-button selection of meter function and
resolution
- Meter accessible for external voltage
measurements
- All outputs short-circuit protected
- Compact, bench-top unit, sources over 120 Watts
|
| TECHNICAL INFORMATION
/ SPECIFICATIONS |
|
OUTPUTS
|
|
Parameter
|
V1
|
+V2
|
-V2
|
V3
|
|
Range
|
0 to 30V
Variable
|
+3V to +15V
Variable
|
-3V to -15V
Variable
|
5V to 6
Variable
|
|
Max. Load
|
2A
|
1A
|
1A
|
5A
|
|
Load regulation (CV)
|
±(0.03% + 3mV)
|
±(0.03% + 3mV)
|
±(0.06% + 6mV)
|
±(0.03% + 3mV)
|
|
Line Regulation (CV)
|
------------------------- ±(0.03% + 2mV)-----------------------------------------------------
|
|
Tracking Error
|
-------------------------V2 tracks + V1 within ±
1%------------------------------------------
|
|
Ripple (CV)
|
-------------------------Less than 1 mVr ms----------------------------------------------------
|
|
Noise (CV)
|
-------------------------Less than 10mV p-p, upto 15
MHz--------------------------------------
|
|
Load Regulation
(CC) upto 30V
|
2mA
±0.2%
|
-
|
-
|
-
|
|
Line Regulation
(CC) for ± 10%
Mains Var.
|
±0.2%
|
-
|
-
|
-
|
|
Ripple (CC)
|
Less than 20mA rms
|
-
|
-
|
-
|
|
Noise (CC)
|
Less than 20mA p-p
|
-
|
-
|
-
|
|
Load effect, transient recovery time
|
----------------- 400 µs to within 5mV of output
setting for a NL to FL change.----------------
|
|
Output Protection
|
--------------------------Short-circuit proof------------------------------------------------------
|
|
Metering Accuracy
|
± (0.25% rdg + 1 dgt) for voltage and ±
(0.5% rdg + 1 dgt) for current
|
|
Resolution
|
10mV upto 20V
100mV upto 30V
10mA upto 2A
|
10mV
|
10mV
|
10mV
|
|
GENERAL
|
|
DVM External Input
|
Ranges : 20V, 200V DC
Resolution : 10mV, 100mV
Accuracy : ±(0.25% rdg + 1 dgt.)
|
|
Power Input
|
230 VAC±10%, 50Hz
|
|
Operating Temperature
|
0°C to 40°C
|
|
Dimensions (mm)
|
317w x 87H x 380D
|
|
Weight (approx.)
|
8 Kg
|
|
|
|