Each 1000D series power supply houses two identical continuously
variable regulated CV/CC, DC-power outputs. A front panel switch selects
either independent or tracking mode. In the "TRACKING" mode,
the negative "slave" power supply voltage tracks the positive
"master" voltage, within ± 1%. In the "INDEPENDENT"
mode, the two supplies can be used separately or in series operation with
independent adjustment of output voltages and current limits. The output
voltage can be continuously adjusted over the specified range by using
coarse and fine voltage controls.
The power supply output are isolated and floating. Two moving coil meters,
accuracy ± 2% F.S.D., with appropriate switches are provided to
monitor output voltage and currents.
|
| |
| TECHNICAL INFORMATION
/ SPECIFICATIONS |
|
Input Voltage
|
230 VAC ± 10%, 50 ± 2 Hz, Single Phase
|
|
Line Regulation
|
±0.05% + 5mV to 20mV*
|
|
Load Regulation
|
0.05% + 5mV to 20mV*
|
|
Riple (Max)
|
1mV RMS
|
|
Tracking Error
|
±1%, between the output-voltages of the two
supplies, in dual tracking mode.
|
|
Protection
|
Short circuit and overload by CV/CL characteristics.
(Current limit settable from about 10% to 110% of rated
value.)
|
|
Ambient Range
|
0 to 50°C
|
|
Metering Accuracy
|
.± 2% of F.S.D
|
|
Transient Response
|
100 µsec to recopvery within
regulation band for 10% to 90% load change
|
|
Temp. Coefficient
|
0.05% + 5mV to 20mV*/°C [After 1/2 hour warm up]
|
|
Stability
|
0.2% + 15mV to 60mV* [After 1/2 hour warm up]
|
|
|
Model No.
|
Output
Voltage
|
Maximum
Current
|
Pre-
Regulator
|
Remote
Sensing
|
Size (mm)
LxDxH
|
|
634150109
|
0± 15V |
1A
|
-
|
-
|
275x210x280
|
|
634150209
|
0± 15V
|
2A
|
-
|
-
|
275x210x280
|
|
634150309
|
0± 15V
|
3A
|
-
|
-
|
483x221x315
|
|
634150506
|
0± 15V
|
5A
|
Provided
|
Provided
|
483x221x310
|
|
634150100
|
0± 15V
|
10A
|
Provided
|
Provided
|
483x221x520
|
|
634300109
|
0± 30V
|
1A
|
-
|
-
|
275x210x280
|
|
634300209
|
0± 30V
|
2A
|
-
|
-
|
275x210x280
|
|
634300309
|
0± 30V
|
3A
|
-
|
-
|
483x221x310
|
|
634300509
|
0± 30V
|
5A
|
Provided
|
Provided
|
483x221x430
|
|
634300100
|
0± 30V
|
10A
|
Provided
|
Provided
|
483x221x430
|
|
634600109
|
0± 60V
|
1A
|
- |
- |
275x210x280
|
|
634600209
|
0± 60V
|
2A
|
-
|
-
|
483x132x310
|
|
634600509
|
0± 60V
|
5A
|
Provided
|
Provided
|
483x221x435
|
|
634600100
|
0± 60V
|
10A
|
Provided
|
Provided
|
483x221x435
|
|
Both output are floating, serialising and master slave
configurations are selectable thereby adding all round
configurability. LED overload indication is provided
for both outputs which signifies current limit operation.
|
|
* Proportional Adder for 15V to 60V output
* Sizes given above are excluding groumets, front plate
components and handles.
|
|
|
|