UPS - T Series

Total compatibility and complete protection for all Pcs

SALIENT FEATURES
  • Wide input operating range
  • Stepped approximation to sine wave in battery mode
  • Internal 12V/7AH SMF battery
  • Internal 12V/7AH SMF X 2 batteries (T660B2, T1002)
  • Compact size
  • Black-start feature
  • Short circuit protection
  • Intelligent battery management
   TECHNICAL INFORMATION / SPECIFICATIONS

Model

T640

T553

T660B2

T1002

Main Operation

Capacity

600VA/360Watts

500VA/300 Watts

650VA/390W

1000VA/600W

Dimensions (WxHxD) & Weight

95x135x275 mm; 5 kg

95x160x320 mm; 7.4 kg

 

 

Nominal Input Voltage

220V/230V/240V

220V/230V/240V

230VCA/50Hz

 

Window for Mains Operation

140 V to 300 VAC

140 V to 300 VAC

140 - 280 VCA

 

Input Frequency

50 Hz (Nominal)

50 Hz (Nominal)

50Hz, Nominal, >40Hz. seesing

 

Output Frequency

 

 

190 - 260VAC

 

Protections

 

 

Overload - Output Trip OFF

 

Battery Operation

Output Voltage

210 - 240VAC (Nominal)

210 - 240VAC (Nominal)

210 - 240VAC/rms

 

Transfer Time (typical)

3 msec. Typical

3 msec. Typical

3 msec. Typical

 

Output Wave Form

Step Sine Wave

Step Sine Wave

Stepped, approximation to Sine Wave

 

Battery Voltage

12V/7AH

* 12V (External)

 

 

Protections

 

 

Short Circuit, Overload Output Trip OFF

 

No. of Internal Batteries

 

 

12V/7AH X 2

12V/7AH X 2

System Voltage

 

 

12 Vdc

24 Vdc

Environment

 

 

0 - 40°C, 95% RH (non condensing)

 

Typical Load

 

 

2PC

3 PC

Typical Run-time

 

 

10 -15 Mins. (15"CRT/17"TFT)

15 - 20 Mins. (15"CRT/17"TFT)

Back-up time with Typical Load

Desktop with 15" Colour Monitor

20 Minutes

20 Minutes

 

 

Desktop with 17" Colour Monitor

14 Minutes

14 Minutes

 

 

Tower with 15" Colour Monitor

14 Minutes

14 Minutes

 

 

Tower with 17" Colour Monitor

12 Minutes

12 Minutes

 

 

* External Charger of 12V/7A can be provided with external battery UPS for Extended Backup.
* Specifications ar subject to change without prior notice.